MIL-STD-962D
w/CHANGE 1
MIL-STD-123B
w/CHANGE 2
3. DEFINITIONS
3.1 General. The definitions used in this standard are in MIL-HDBK-123.
4. GENERAL REQUIREMENTS
4.1 Calibration. Reference pieces for calibration shall be of the same material, metal travel distance, surface finish, and ultrasonic response as the bar stock being tested.
4.1.1 Reference test piece for bar stock 5/8-inch to 1-1/2-inch diameter. The reference test piece shall be a bar of at least 3 feet in length. For near zone testing, metal travel shall be 4/10 the diameter and 9/10 the diameter of the test piece to flat bottom holes (FBHs) 0.02 inches in diameter. For far zone testing, metal travel shall be 6/10 the diameter and 1/10 the diameter of the test piece to FBHs 0.02 inches in diameter.
4.1.2 Reference test piece for bar stock 1/2-inch to 5/8-inch diameter. The reference test piece shall be a bar of at least 3 feet in length. For near zone testing, metal travel shall be 4/10 the diameter and 9/10 the diameter of the test piece to FBHs 0.02 inches in diameter of 0.062-inch depth. For far zone testing, metal travel shall be 6/10 the diameter and 1/10 the diameter of the test piece with metal travel 0.06 inch to a FBH of 0.02 inch diameter.
4.1.3 Reference test piece for bar stock less than 1/2-inch diameter. For bar stock less than 0.5-inch diameter, only one FBH providing 1/2 diameter travel shall be
required.
(THE EXAMPLE ENDS HERE, BUT THE SAME TYPE OF FORMAT WOULD CONTINUE UNTIL THE END OF THE STANDARD, WITH VERTICAL LINES OR OTHER MARKING DENOTING WHERE CHANGES, DELETIONS, OR ADDITIONS WERE MADE. AS REQUIRED BY 5.18.4, THE FOLLOWING
NOTATION WOULD BE INCLUDED AS THE LAST PARAGRAPH IN SECTION 6.)
6.5 Change notations. The margins of this standard are marked with vertical
lines to indicate modifications generated by this change. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations.
FIGURE 7. Example of change to standard - Continued.
50
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.