A.2.2 Test set-up.
A.2.2.1 Longitudinal scan. While maintaining correct water path, obtain a 2-inch signal from the highest attenuated 0.02-inch FBH. Adjust sensitivity and distance amplitude control to bring near and far FBHs within 10 percent of a 2-inch amplitude indication. Compatibility between reference block and the material to be tested shall be established by comparing the first unsaturated back reflection from the block with the corresponding back reflection from the material to be tested. Gain shall be set to give an
80 percent of screen signal from the FBH with depth of 6/10 the diameter of the test piece. Compatibility shall be checked in at least three well-separated areas on the material to be tested. The gate width for near zone testing shall be set to include response from FBH with depth of 1/10 and 6/10 test piece diameter. The gate width for far zone testing shall be set to include response from FBH with depth of 4/10 and 9/10 test piece diameter. The alarm sensitivity shall be set to assure 100 percent of a 0.02-inch diameter FBH inspection level.
A.2.2.2 Loss of backface. Set instrument so the first backface reflection from the full round reference block is 80 percent of screen saturation. The first backface reflection shall be gated and set alarm at 50 percent or less of loss in backface signal. Inspect and evaluate loss of backface areas.
A.2.2.3 Angle scan test. Position transducer over angle reference notch area for maximum response. Rotate reference standard so center of standard block and notch are on a horizontal plane. Adjust gain to obtain a 2-inch signal and adjust flaw alarm for a 1-inch signal. Gate width shall be set to include the area at which the signal from the reference notch is detected.
A.3 Acceptance levels.
A.3.1 Longitudinal scan. Discontinuities in excess of the response from a 0.2-inch diameter FBH at the estimate discontinuity depth shall not be acceptable.
A.3.2 Loss of back reflection. Any loss of back reflection in excess of 50 percent of full saturation of the screen shall be considered unacceptable with the instrument set so the first back reflection from the correct test block is at 80 percent of the screen adjusted for nonlinearity.
FIGURE 6. Example of appendix - Continued.