1. Purpose. This requirement establishes criteria for test provisions.
2. Documents applicable to Requirement 32:
MIL-STD-415 Test Provisions for Electronic Systems and Associated
Equipment, Design Criteria for
MIL-STD-2165 Testability Program for Electronic Systems and
Equipment
3. Definitions. Not applicable.
4. Requirements
4.1 Built-in test devices. Built-in test devices shall maintain their accuracy under all operating conditions required by the equipment under test. These devices shall be provided with connections or access for their operational checkout or calibration.
4.2 External test points. Protection shall be provided in the test point circuitry to prevent equipment damage caused by the external grounding of test points.
4.3 Failure effect. Provisions for testing shall be so designed that any failure of built-in test devices will not degrade equipment operating or cause equipment shut down.
4.4 Test provisions. Test provisions to provide means for monitoring performance, calibration, calibration, and fault isolation shall be in accordance with MIL-STD-415.
5. Information for guidance only
5.1 Testability program. When specified by the contracting activity, a testability program should be implemented in accordance with MIL-STD-2165.
(THIS IS AN EXAMPLE ONLY. THE REQUIREMENT IS IN 5.11.1.)
FIGURE 4. Example of individual requirement.